DAC M60

A class of compact, lightweight and versatile DAC MV cable test systems with withstand voltage test, PD analysis and PD localization

The “Damped Alternating Current” (DAC) test systems M30, M40 and M60 form an exceptionally compact, lightweight and versatile class of systems for testing and diagnosing Medium-voltage transmission cables. They are programmable and have automatic withstand voltage testing, partial discharge (PD) measurement and analysis as well as PD localization. The controls, measurement and presentation of results is user-friendly, with a common software platform for the entire range of our products.

A DAC cable test does not just provide a rudimentary “good/bad” statement, it is an advanced analysis and diagnostic concept. It enables the condition of the cable insulation to be assessed of newly installed, repaired or in-service cable systems and thus supports the asset management process of the cable operator.

  • Our Brochures Download
  • Get In Touch For A Consultation

Technical Data

The measurement modes include:

  • Withstand voltage test with operating voltage, but also above it
  • Partial discharge measurement, analysis and localization along complete cable systems

The DAC voltage test and PD analysis enables the reliable detection of:

  • Defects in the cable insulation due to installation or routing
  • Defects in the cable fittings, i.e. joints and terminations
  • Damage to the cable insulation due to ageing processes

Properties

Compact, easy to transport, versatile in use

Extra

Additional capacity for testing short cables is included

Max. Output voltage

30 / 40 / 60 kV

DAC frequency range

20 – 1000 Hz

Cable length

up to 20 km

PD Resolution

1 pC

Supply voltage

94 – 250 V

Standard

Cable testing according to IEC 60270, IEC60060-3

Addition

PRPDA sample, IEEE-compliant operating andsafetydevice, socket and fault location